Rework usages/naming of configuration macros [part 1] (#2793)

There are quite a few configuration macros in the project.
As discussed in the #2520 issue there are a few awkward constructs.

Main changes:

* Renamed all CONFIG_DISABLE_<name>_BUILTIN macro to JERRY_BUILTIN_<name> format.
* The special JERRY_BUILTINS macro specifies the basic config for all es5.1 builtins.
* Renamed all CONFIG_DISABLE_ES2015_<name> to JERRY_ES2015_<name> format.
* The special JERRY_ES2015 macro specifies the basic config for all es2015 builtins.
* Renamed UNICODE_CASE_CONVERSION to JERRY_UNICODE_CASE_CONVERSION.
* Renamed ENABLE_REGEXP_STRICT_MODE to JERRY_REGEXP_STRICT_MODE.
* All options (in this change) can have a value of 0 or 1.
* Renamed ENABLE_REGEXP_STRICT_MODE to JERRY_REGEXP_STRICT_MODE.
  JERRY_REGEXP_STRICT_MODE is set to 0 by default.
* Reworked CONFIG_ECMA_NUMBER_TYPE macro to JERRY_NUMBER_TYPE_FLOAT64 name and now
  it uses the value 1 for 64 bit floating point numbers and 0 for 32 bit floating point
  number.
  By default the 64-bit floating point number mode is enabled.
* All new JERRY_ defines can be used wit the `#if ENABLED (JERRY_...)` construct to
  test if the feature is enabled or not.
* Added/replaced a few config.h includes to correctly propagate the macro values.
* Added sanity checks for each macro to avoid incorrectly set values.
* Updated profile documentation.
* The CMake feature names are not updated at this point.

JerryScript-DCO-1.0-Signed-off-by: Peter Gal pgal.u-szeged@partner.samsung.com
This commit is contained in:
Péter Gál
2019-04-09 10:14:46 +02:00
committed by Robert Fancsik
parent 722d092528
commit 40f7b1c27f
213 changed files with 1902 additions and 1649 deletions
+10 -10
View File
@@ -259,12 +259,12 @@ ecma_op_to_number (ecma_value_t value) /**< ecma value */
ecma_string_t *str_p = ecma_get_string_from_value (value);
return ecma_make_number_value (ecma_string_to_number (str_p));
}
#ifndef CONFIG_DISABLE_ES2015_SYMBOL_BUILTIN
#if ENABLED (JERRY_ES2015_BUILTIN_SYMBOL)
if (ecma_is_value_symbol (value))
{
return ecma_raise_type_error (ECMA_ERR_MSG ("Cannot convert a Symbol value to a number."));
}
#endif /* !CONFIG_DISABLE_ES2015_SYMBOL_BUILTIN */
#endif /* ENABLED (JERRY_ES2015_BUILTIN_SYMBOL) */
if (ecma_is_value_object (value))
{
@@ -360,12 +360,12 @@ ecma_get_number (ecma_value_t value, /**< ecma value*/
return ECMA_VALUE_EMPTY;
}
#ifndef CONFIG_DISABLE_ES2015_SYMBOL_BUILTIN
#if ENABLED (JERRY_ES2015_BUILTIN_SYMBOL)
if (ecma_is_value_symbol (value))
{
return ecma_raise_type_error (ECMA_ERR_MSG ("Cannot convert a Symbol value to a number."));
}
#endif /* !CONFIG_DISABLE_ES2015_SYMBOL_BUILTIN */
#endif /* ENABLED (JERRY_ES2015_BUILTIN_SYMBOL) */
JERRY_ASSERT (ecma_is_value_boolean (value));
@@ -435,13 +435,13 @@ ecma_to_op_string_helper (ecma_value_t value) /**< ecma value */
{
return ecma_get_magic_string (LIT_MAGIC_STRING_NULL);
}
#ifndef CONFIG_DISABLE_ES2015_SYMBOL_BUILTIN
#if ENABLED (JERRY_ES2015_BUILTIN_SYMBOL)
else if (ecma_is_value_symbol (value))
{
ecma_raise_type_error (ECMA_ERR_MSG ("Cannot convert a Symbol value to a string."));
return NULL;
}
#endif /* !CONFIG_DISABLE_ES2015_SYMBOL_BUILTIN */
#endif /* ENABLED (JERRY_ES2015_BUILTIN_SYMBOL) */
JERRY_ASSERT (ecma_is_value_boolean (value));
if (ecma_is_value_true (value))
@@ -488,14 +488,14 @@ ecma_op_to_prop_name (ecma_value_t value) /**< ecma value */
{
ecma_check_value_type_is_spec_defined (value);
#ifndef CONFIG_DISABLE_ES2015_SYMBOL_BUILTIN
#if ENABLED (JERRY_ES2015_BUILTIN_SYMBOL)
if (ecma_is_value_symbol (value))
{
ecma_string_t *symbol_p = ecma_get_symbol_from_value (value);
ecma_ref_ecma_string (symbol_p);
return symbol_p;
}
#endif /* !CONFIG_DISABLE_ES2015_SYMBOL_BUILTIN */
#endif /* ENABLED (JERRY_ES2015_BUILTIN_SYMBOL) */
return ecma_to_op_string_helper (value);
} /* ecma_op_to_prop_name */
@@ -526,12 +526,12 @@ ecma_op_to_object (ecma_value_t value) /**< ecma value */
{
return ecma_copy_value (value);
}
#ifndef CONFIG_DISABLE_ES2015_SYMBOL_BUILTIN
#if ENABLED (JERRY_ES2015_BUILTIN_SYMBOL)
else if (ecma_is_value_symbol (value))
{
return ecma_op_create_symbol_object (value);
}
#endif /* !CONFIG_DISABLE_ES2015_SYMBOL_BUILTIN */
#endif /* ENABLED (JERRY_ES2015_BUILTIN_SYMBOL) */
else
{
if (ecma_is_value_undefined (value)